Protein ladders are essential for estimating molecular weights, tracking electrophoresis progress, and confirming successful transfer in SDS-PAGE and Western blotting. But like any lab tool, they’re not immune to mishandling or degradation — and small errors can lead to big inconsistencies in your results.
In this post, we’ll walk through the most common problems researchers encounter with pre-stained protein ladders — and how to prevent them.
1. Smeared or Diffuse Bands
What it means: Bands appear blurry, uneven, or drag across the gel instead of forming clean lines.
Possible causes:
-
Repeated freeze-thaw cycles
-
Overloading the gel lane
-
Degraded marker proteins
-
Impure or old running buffer
How to avoid it:
-
Aliquot the ladder into small tubes on first use to avoid repeated freeze-thawing.
-
Load no more than the recommended volume (typically 3–5 µL per lane).
-
Use fresh running buffer and ensure proper polymerization of your gel.
✅ NuSep’s Pre-Stained Protein Ladder is formulated with anti-smearing stabilizers and shipped with cold protection to help preserve band sharpness during storage and transit.
──────────────────────────────────────
2. Missing Bands

What it means: One or more expected ladder bands are faint or entirely absent.
Possible causes:
-
Low protein concentration due to degradation
-
Incomplete transfer (for Western blotting)
-
Ladder diluted too far or loaded too little
How to avoid it:
-
Store at –20°C and protect from repeated thawing.
-
Verify transfer conditions are optimized.
-
Stick to recommended dilution and use protein-compatible loading dye.
──────────────────────────────────────
3. Incorrect Band Migration

What it means: Marker bands do not align with expected molecular weight positions.
Possible causes:
-
Incomplete polymerization of the gel
-
High salt concentration or incorrect buffer composition
-
Overloaded or uneven gel wells
How to avoid it:
-
Always prepare fresh gel solutions or use high-quality precast gels.
-
Use the correct buffer system (e.g., Tris-Glycine-SDS).
-
Load samples gently and avoid disturbing the wells.
──────────────────────────────────
4. Reduced Band Intensity Over Time
What it means: Bands become faint after multiple uses or prolonged storage.

Possible causes:
-
Repeated freeze-thawing
-
Ladder stored at room temp or in a frost-free freezer
-
Ladder has passed its expiration date
How to avoid it:
-
Store in a manual-defrost freezer or at 4°C for short-term use.
-
Use glycerol-based ladders with cryo-stabilizers.
-
Check the expiration date and look for consistent performance.
Keep Your Ladder Working for You
Issue | Cause | Solution |
---|---|---|
Smeared bands | Overloading, degradation | Aliquot, use fresh buffer |
Missing bands | Degradation, transfer loss | Optimize storage and loading |
Migration errors | Gel/buffer issues | Use correct gel system |
Faint bands | Age, freeze-thaw | Follow proper storage & shelf life |